Powermonitor 3000Master ModuleCatalog Numbers 1404-M4, 1404-M5, 1404-M6, 1404-M8Installation InstructionsTopic PageImportant User Information 2About T
10 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Catalog Number ExplanationThe Powermonitor 3000 unit has the followi
Powermonitor 3000 Master Module 11Publication 1404-IN007F-EN-P - November 2009Quick Start GuidelinesThe Powermonitor 3000 unit may be used in many
12 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Install the Powermonitor 3000 UnitOnly qualified personnel should in
Powermonitor 3000 Master Module 13Publication 1404-IN007F-EN-P - November 2009Mount the master module so that the metal grounding clips on the bot
14 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Product DimensionsUse the dimensions in these drawings when mounting
Powermonitor 3000 Master Module 15Publication 1404-IN007F-EN-P - November 2009Master Module SpacingPowermonitor 3000Powermonitor 3000Powermonitor
16 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009System Accuracy ConsiderationsUser-supplied potential transformers (
Powermonitor 3000 Master Module 17Publication 1404-IN007F-EN-P - November 2009Phase ErrorPhase shift between the primary to secondary signals is a
18 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Wiring and Connecting the Power MonitorWiring of the power monitor i
Powermonitor 3000 Master Module 19Publication 1404-IN007F-EN-P - November 2009Wiring the Master ModuleObserve all wire lug sizes and screw torques
2 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Important User InformationSolid state equipment has operational chara
20 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009The shorting terminal block should be located adjacent to the Powerm
Powermonitor 3000 Master Module 21Publication 1404-IN007F-EN-P - November 2009Wiring DiagramsSingle-phase Direct Connection Wiring Diagram (System
22 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Single-phase with PTs Wiring DiagramLoadCustomerChassisGroundCustome
Powermonitor 3000 Master Module 23Publication 1404-IN007F-EN-P - November 2009Three-phase Four-wire Wye Direct Connect Wiring Diagram(Systems <
24 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Three-phase Four-wire with PT’s Wiring DiagramLoadCustomerChassisGro
Powermonitor 3000 Master Module 25Publication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Grounded Wye Direct Connection Wiring Diagram
26 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Grounded Wye with PTs Wiring DiagramLoadCusto
Powermonitor 3000 Master Module 27Publication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Delta with Three PTs and Three CTs Wiring Dia
28 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Delta with Three PTs and Two CTs Wiring Diagr
Powermonitor 3000 Master Module 29Publication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Open Delta with Two PTs and Three CTs Wiring
Powermonitor 3000 Master Module 3Publication 1404-IN007F-EN-P - November 2009About This PublicationExcept as noted, refer to the Powermonitor 3000
30 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Open Delta with Two PTs and Two CTs Wiring Di
Powermonitor 3000 Master Module 31Publication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Grounded L2(B) Phase Open Delta Direct Connec
32 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Delta Direct Connect with Three CTs Wiring Di
Powermonitor 3000 Master Module 33Publication 1404-IN007F-EN-P - November 2009Three-phase Three-wire Delta Direct Connect with Two CTs Wiring Diag
34 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Control PowerThe power monitor draws a nominal 15VA control power. C
Powermonitor 3000 Master Module 35Publication 1404-IN007F-EN-P - November 2009All Status Inputs are common to an internal 24V DC source on the SCO
36 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009The KYZ output is a solid-state relay designed for low-current switc
Powermonitor 3000 Master Module 37Publication 1404-IN007F-EN-P - November 2009Native RS-485 Communication WiringThe RS-485 communication standard
38 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009RS-485 ConnectionsShield Connection(See Note 4)IBM Compatible Person
Powermonitor 3000 Master Module 39Publication 1404-IN007F-EN-P - November 2009Optional RS-232 CommunicationPowermonitor 3000 units with a catalog
4 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Safety Considerations PT Potential transformer (also known as VT in s
40 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Optional Remote I/O CommunicationPowermonitor 3000 units with a cata
Powermonitor 3000 Master Module 41Publication 1404-IN007F-EN-P - November 2009Configuration options for optional remote I/O communication include
42 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Optional DeviceNet CommunicationPowermonitor 3000 units with a catal
Powermonitor 3000 Master Module 43Publication 1404-IN007F-EN-P - November 2009Connecting Powermonitor 3000 to Other DeviceNet DevicesOptional Ethe
44 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Powermonitor 3000 Ethernet Network ExampleEthernet Wiring Connection
Powermonitor 3000 Master Module 45Publication 1404-IN007F-EN-P - November 2009Refer to the note at the beginning of Communication Wiring on page 3
46 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Refer to the following documentation for ControlNet network wiring r
Powermonitor 3000 Master Module 47Publication 1404-IN007F-EN-P - November 2009The 1786-CP cable can be plugged into any ControlNet product’s NAP t
48 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Powermonitor 3000 Status IndicatorsRS-485 Status IndicatorsAll Power
Powermonitor 3000 Master Module 49Publication 1404-IN007F-EN-P - November 2009RS-232 Status IndicatorsRemote I/O Status IndicatorsRS-232 Optional
Powermonitor 3000 Master Module 5Publication 1404-IN007F-EN-P - November 2009About the Power MonitorThe Bulletin 1404 Powermonitor 3000 unit is un
50 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009DeviceNet Status IndicatorsEtherNet/IP Status IndicatorsDeviceNet Op
Powermonitor 3000 Master Module 51Publication 1404-IN007F-EN-P - November 2009ControlNet Status IndicatorsF2 Off Not used.Network Status Off No po
52 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Access Self-test and Diagnostic DataYou can access valuable diagnost
Powermonitor 3000 Master Module 53Publication 1404-IN007F-EN-P - November 2009Refer to the Powermonitor 3000 Unit User Manual, publication 1404-UM
54 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Cleaning Instructions1. Turn off all electrical power supplied to th
Powermonitor 3000 Master Module 55Publication 1404-IN007F-EN-P - November 2009Field Service ConsiderationsIf the power monitor requires servicing,
56 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009SpecificationsMeasurement Accuracy and RangePowermonitor 3000 Master
Powermonitor 3000 Master Module 57Publication 1404-IN007F-EN-P - November 2009Current sense inputs: I1, I2, I3, I4 Overload withstand: 15 A contin
58 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Technical Specifications - 1404-M4, 1404-M5, 1404-M6, 1404-M8Attribu
Powermonitor 3000 Master Module 59Publication 1404-IN007F-EN-P - November 2009Product ApprovalsPowermonitor 3000 units have the following approval
6 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009The Powermonitor 3000 unit is a microprocessor-based monitoring and c
60 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009CE CertificationIf this product bears the CE marking, it is approved
Powermonitor 3000 Master Module 61Publication 1404-IN007F-EN-P - November 2009Additional ResourcesRefer to these power and energy management docum
62 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009Notes:
Powermonitor 3000 Master Module 63Publication 1404-IN007F-EN-P - November 2009Notes:
Publication 1404-IN007F-EN-P - November 2009 PN-55982Supersedes Publication 1404-IN007E-EN-P - October 2006 Copyright © 2009 Rockwell Automation, Inc.
Powermonitor 3000 Master Module 7Publication 1404-IN007F-EN-P - November 2009CommunicationEvery Powermonitor 3000 unit comes with a native RS-485
8 Powermonitor 3000 Master ModulePublication 1404-IN007F-EN-P - November 2009 Master Module with Communication OptionsPowermonitor 3000wermonitor
Powermonitor 3000 Master Module 9Publication 1404-IN007F-EN-P - November 2009Powermonitor 3000 Display ModuleThe display module is an optional use