Vedere la pagina 16
Sensor Cable Guidelines
Entek 9000 Series Sensor Installation Guide 9
Sensor Cable Guidelines
This section describes some common cable guidelines to get the signal from the sensor to
the monitoring device.
Sensor Connections and Power
Most of the 9000 series sensors are two-wire, IEPE accelerometers. There are also 9000
series sensors that have a built-in integrator to produce a velocity signal, as well as
combination accelerometer/temperature sensors. The pin connections on the sensors are
listed in the following table.
Combination accelerometer/temperature sensors have three pins.
Connector Pin Function
Shell Ground, connected to cable shield
A IEPE sensor power and signal
B IEPE sensor signal return (signal common)
Connector Pin Function
Shell Ground, connected to cable shield
A IEPE sensor power and signal
B IEPE sensor signal return (signal common) and temperature common
C Temperature sensor signal and power
S
ide View
End View
AB
S
ide View
End View
AC
B
Vedere la pagina 16